Laboratory IntegrationGuide
Installation validation & go-live checklist
Evidence required before any native laboratory installation can carry Production orders.
Current availability
Limitation
No native installation can be approved today. The checklist below describes the release-readiness process; the platform-side items are in progress and are not complete.
Platform readiness (Solia)
- Tenant-scoped claiming, result scheduling and Edge work authorities available in Solia Core.
- Hosted gateway and Edge infrastructure with key custody, monitoring, alerting, backup and rollback.
- End-to-end proof: order → acknowledgement → accession → accepted specimen → final and corrected result → Partner API, including crash and retry cases.
- Security review and business associate agreements covering every component that handles PHI.
Installation readiness (per laboratory)
- Interface specification, vendor product and version, and any required interface license supplied by the laboratory.
- Installation-specific endpoint, network path and credentials provisioned into Solia's secret store.
- Code mappings for every orderable and result approved.
- Test-system exchange of orders, ACKs and results, including duplicate, rejection and correction cases.
- Laboratory clinical and IT sign-off.
- Installation approved and bound to one workspace and environment; Production readiness then follows the standard validation path.