⌘K

Laboratory IntegrationGuide

Connectivity availability & certification status

Which laboratory transports are executable today, which are implemented but gated, and what certification means.

On this page

Three tiers

  • Available — the HTTPS/JSON Solia Lab Contract (solia.lab.v1) and the Solia Test Laboratory in Sandbox. A laboratory can configure, test and validate these itself.
  • Implemented, not enabled — native REST, FHIR R4, HL7 v2/MLLP, SFTP/file and the private-network Edge agent. The code exists and passes isolated local tests, but runtime gates are off and no installation is approved.
  • Installed — a specific laboratory installation that has completed validation and approval. No installation of any native transport exists today.

Important

Solia does not offer zero-code, plug-and-play connectivity to any LIS today. Every native connection requires an installation-specific endpoint, a laboratory or vendor interface license where applicable, approved code mappings, security review and clinical sign-off.

Status matrix

text
Transport                                        Status                     Certification
HTTPS/JSON Solia Lab Contract (solia.lab.v1)     Available                  Self-service Sandbox connection test and Production validation
Native REST (laboratory-defined JSON API)        Implemented, not enabled   No laboratory installation validated
FHIR R4 (ServiceRequest / DiagnosticReport)      Implemented, not enabled   No FHIR server or vendor product certified
HL7 v2 over MLLP (via gateway)                   Implemented, not enabled   No LIS vendor or version certified
SFTP / delimited file                            Implemented, not enabled   No hosted SFTP installation validated
Private-network Edge agent                       Implemented, not enabled   Not deployed; no signed release distributed

What certification means here

  • Local wire test — the protocol code exchanges real bytes with a local test peer. It proves framing and parsing, not interoperability with a vendor product.
  • Installation validation — orders, acknowledgements and results exchanged with one laboratory's own test system using approved mappings.
  • Clinical sign-off — the laboratory's clinical and IT owners confirm results reach release correctly. Only the laboratory can give this.

Solia publishes no vendor- or version-specific conformance claim until an installation has passed validation with that product.

Choosing a path today

  • Can expose or build an HTTPS endpoint → use the HTTPS/JSON contract (Laboratory connection).
  • Requires HL7 v2, FHIR or file exchange → submit a managed integration request; it is tracked in the Control Plane and does not by itself create a live interface.
  • Evaluating only → use the Solia Test Laboratory in Sandbox. Sandbox proof is never Production validation.