Reference specimen custody and accession evidence

Exact pure state transitions, actor sources, handling, individual rejection and canonical persistence gaps.

On this page

Current availability — October 25, 2026

Limitation

Reference Testing is NOT available in Production and is NOT operational in Sandbox. The relationship, Program-binding and order-link database packages are staged and unapplied, both reference gates are off, no native installation registry exists and no clinical mapping authority has been established. The Control Plane shows "Reference Testing configuration pending" and every action is disabled with its reason.

Everything below describes engineering source contracts and isolated test evidence (disposable PostgreSQL, loopback PostgREST, test-signed tokens). Where a behavior is described as "designed", it exists in source and isolated tests only — not as a joined, persisted canonical R1 workflow. This is not an availability, certification or publication announcement.

Fact ledger versus clinical persistence

applyCustodyEvent is a pure in-memory contract over per-specimen evidence; it is not a canonical specimen writer or courier integration. Current R1 has no persisted custody chain or performing accession. Do not label a displayed designed stage as an operational event.

text
none → prepared
prepared → dispatched | rejected
dispatched → carrier_in_transit | carrier_delivered | performer_received
carrier_in_transit → carrier_delivered | performer_received
carrier_delivered → performer_received
performer_received → accessioned | rejected
accessioned → processing | rejected
processing → rejected
rejected → recollection_requested
recollection_requested → [no further transition in this contract]

Required evidence and allowed source

CustodyEvent names specimenId, orderId, to, actor, source, occurredAt and correlationId. accession, handling and reason are conditionally required. actor and correlationId must be nonempty; occurredAt must parse as time and cannot regress behind the specimen’s previous event.

  • prepared and dispatched require sender_lab source.
  • carrier_in_transit and carrier_delivered require carrier_evidence. No carrier client or integration is provided.
  • performer_received, accessioned, processing, rejected and recollection_requested require performer_lab source.
  • accessioned requires a distinct accession identifier; receipt does not infer it.
  • rejected and recollection_requested require reason; governed prepared/performer_received events require handling evidence.

Nonlinear receipt does not fabricate carrier facts

The contract permits dispatched directly to performer_received, because actual receiving evidence may exist without a carrier feed. It must not create carrier_in_transit or carrier_delivered events in between. Similarly a carrier delivery scan never creates performer receipt or accession.

  1. Correlate the real event to the existing order and exact specimen.
  2. Verify authoritative actor/source and chronological timestamp; refuse a foreign order or missing correlation.
  3. Check allowed transition and governed container/volume/preparation/handling evidence.
  4. Append only that specimen event. Preserve other specimens without cancellation.
  5. For accession, record actual B accession separately from sender reference and kit barcode.

Partial rejection and recollection

orderCustodySummary distinguishes none_rejected, partial_rejection and whole_kit_rejected; orderCanceled is always false in this source summary. One rejected specimen affects only its ledger entry. Recollection is a recorded request, not an automatic replacement order, new kit or courier booking.

  • custody_evidence_incomplete: repair source evidence, never fabricate actor/time.
  • custody_source_not_authoritative: obtain performer/carrier evidence as appropriate.
  • specimen_order_mismatch or custody_time_regression: hold and investigate correlation.
  • accession_identifier_required or governed_handling_evidence_required: wait for actual governed evidence.

Conformance boundary

Verify every allowed edge and prohibited jump in a disposable future canonical implementation, including individual rejection with a second specimen unchanged. Current tests prove source transition rules only. Production custody and clinical acceptance remain unavailable.